01
SCADA Monitoring
Monitor machines, equipment and sensors in real time.
THE PLATFORM
Connect plant-floor equipment, energy infrastructure and industrial data in a secure On-Premise platform.
CAPABILITIES
Explore any capability card below to inspect architecture, industrial protocols, live telemetry, and verified factory case studies.
01
Monitor machines, equipment and sensors in real time.
02
Track electrical consumption, demand and energy performance.
03
Analyze voltage, current, frequency, harmonics and power quality.
04
Visualize analog and digital sensor data with historical analysis.
05
Act on critical conditions with clear, configurable alarm workflows.
06
Build interactive 2D and 3D views for machines and processes.
Harmonic Distortion Spectral Analysis, Microsecond Voltage Sag Recording & Power Factor Optimization
Modern variable frequency drives (VFDs), servo systems, robotic arms, and induction furnaces generate non-linear currents that distort factory voltage waveforms. RockLyzor Power Quality performs Class A continuous monitoring to analyze Total Harmonic Distortion (THD) up to the 63rd order, capture voltage sags and swell transients, and maintain power factor correction banks to shield sensitive CNC machinery from costly failures.
Continuous Industrial Scan
Voltage THD (V-THD)
1.74 %
IEEE 519 limit < 5.0%
Current THD (I-THD)
5.82 %
Within distribution limits
Power Factor (cos φ)
0.984 Lag
Zero reactive billing penalty
Voltage Unbalance
0.38 %
IEC limit < 2.0%
Enterprise-grade functionality engineered for plant-floor reliability
Continuous Fourier analysis of phase voltages and line currents from the 1st through the 63rd harmonic order, isolating critical 5th, 7th, 11th, and 13th harmonic currents that overheat transformer windings.
Sub-cycle RMS evaluation (< 10ms trigger) detecting grid switching transients, lightning surges, and voltage sags caused by heavy motor startup across the municipal feeder.
Accurate decomposition of active (kW), reactive (kVAR), and apparent (kVA) power with automated step recommendation for power factor correction capacitor banks to eliminate utility penalties.
Continuous computation of Voltage Unbalance Factor (% VUF) and zero-sequence triplen harmonic currents (3rd, 9th, 15th) circulating in neutral conductors, preventing motor derating.
Native multi-vendor communication without third-party OPC middleware licenses or external bridges.
Air-Gapped OT Network Architecture
Runs entirely within local manufacturing subnets (VLANs). No cloud uplink required for operations or real-time HMI rendering.
Deterministic performance metrics verified on industrial server environments.
Operational Challenge
Random spindle drive inverter faults and transformer insulation overheating caused catastrophic scrap events averaging $62,000/month with zero diagnostic clues.
RockLyzor Deployment
Installed RockLyzor Power Quality continuous monitoring on main 400V busbars with automated harmonic threshold traps.
Measured Results
DEPLOYMENT
RockLyzor is deployed On-Premise, close to the systems it monitors. Your teams retain control of data, network architecture and access.
Start with your operation
Discover how RockLyzor can centralize your industrial data and give your team real-time operational visibility.