RockLyzor Logo

RockLyzor

Monitor. Analyze. Optimize.

THE PLATFORM

One Operational View Across Your Factory

Connect plant-floor equipment, energy infrastructure and industrial data in a secure On-Premise platform.

CAPABILITIES

Built for the Reality of Industrial Operations

Explore any capability card below to inspect architecture, industrial protocols, live telemetry, and verified factory case studies.

01

SCADA Monitoring

Monitor machines, equipment and sensors in real time.

02

Energy Monitoring

Track electrical consumption, demand and energy performance.

03

Power Quality

Analyze voltage, current, frequency, harmonics and power quality.

04

Sensor Analytics

Visualize analog and digital sensor data with historical analysis.

Active Detail

05

Alarms & Alerts

Act on critical conditions with clear, configurable alarm workflows.

06

Industrial Synoptics

Build interactive 2D and 3D views for machines and processes.

ISA-18.2 / IEC 62682 RATIONALIZATIONISA-18.2 Alarm Management LifecycleIEC 62682 Implementation

Alarms & Alerts

Intelligent Alarm Prioritization, Flood Suppression & Audit-Ready SOE Recording

Operator cognitive overload and alarm flooding during plant emergency trips are among the leading root causes of catastrophic industrial safety events. RockLyzor Alarms & Alerts adheres strictly to the international ISA-18.2 lifecycle standard: enforcing rationalized 4-tier priorities, dynamic deadbands to eradicate chattering nuisance signals, state-based suppression, and escalated multi-channel alerting to ensure technicians act decisively.

Compliance:ISA-18.2 Alarm Management LifecycleIEC 62682 ImplementationEEMUA 191 GuidelinesFDA 21 CFR Part 11 Audit Trail

Live Telemetry State

Continuous Industrial Scan

On-Prem Engine OK

Active Alarm Queue

1 Low, 0 Critical

EEMUA compliant safe zone

Mean Time to Acknowledge

28 seconds

EEMUA target < 60s

Suppressed Nuisance Alarms

142 filtered today

Zero flood conditions

SOE Buffer Integrity

100% Verified

Audit trail fully synced

Bus cycle frequency: 50msData loss protection: Active

Core Architectural Features

Enterprise-grade functionality engineered for plant-floor reliability

01

ISA-18.2 Priority Classification

Strict 4-tier classification (Emergency, High, Medium, Low) calibrated to ensure control room operators face fewer than 1 alarm per 10 minutes under steady-state operating conditions.

Eliminates operator alarm fatigue and desensitization
02

Alarm Flood Suppression & Dynamic Deadbands

Hysteresis deadbands and configurable on/off debounce timers prevent signals hovering near thresholds from firing repeatedly. Parent-child suppression silences secondary trips when a main circuit breaker opens.

Reduces nuisance chattering by over 90%
03

Multi-Tier Escalation Matrix

Automated routing through plant-floor sound klaxons, control screen annunciator banners, SMS, Email, and webhook integrations with tiered escalation if critical alarms remain unacknowledged.

Escalates to standby managers after configurable timeout
04

1-Millisecond Sequence of Events (SOE)

Cryptographically timestamped chronological audit trail of all trip sequences, operator acknowledgments, shelved alarms, and setpoint modifications, compliant with FDA 21 CFR Part 11.

Pinpoints root cause in milliseconds during forensic audits

Industrial Protocols & Interfaces

Native multi-vendor communication without third-party OPC middleware licenses or external bridges.

OPC UA Alarms & Conditions (A&C)Syslog RFC 5424 Audit StreamSNMP Traps v2c / v3SMTP TLS Secure Email AlertsRESTful Webhooks (PagerDuty / Slack / Teams)Hardware GSM/LTE Cellular Modem (SMS Fallback)

Air-Gapped OT Network Architecture

Runs entirely within local manufacturing subnets (VLANs). No cloud uplink required for operations or real-time HMI rendering.

Technical Specifications

Deterministic performance metrics verified on industrial server environments.

Timestamping Resolution1 millisecond Sequence of Events (SOE) accuracy
Priority ClassesEmergency (Priority 1), High (2), Medium (3), Low (4), Diagnostic
Alarm Flood ThresholdConfigurable alert triggered when > 10 alarms occur in 10 minutes
Nuisance FilteringConfigurable hysteresis deadbands (0.5% to 15%) and time-delays
Operator AcknowledgmentMandatory operator reason logging and digital signature audit
Shelving ArchitectureTime-limited shelving with auto-unshelve safety overrides
Verified Factory Case StudyIndustry: Petrochemical Tank Farm & Fluid Distribution Terminal

Operational Challenge

During sudden emergency steam boiler trips, operators were inundated with 280+ unprioritized alarms within 90 seconds, causing technicians to miss a critical high-level tank overflow alert.

RockLyzor Deployment

Implemented RockLyzor ISA-18.2 rationalized alarm management with parent-child state suppression and redundant SMS modem alerting.

Measured Results

  • 94% reduction in alarm counts during emergency boiler shutdowns
  • Average operator acknowledgment time plunged from 7.5 minutes to 28 seconds
  • Passed full environmental and functional safety inspection with zero citations
Switch Capability:

DEPLOYMENT

Control Stays Inside Your Infrastructure

RockLyzor is deployed On-Premise, close to the systems it monitors. Your teams retain control of data, network architecture and access.

Local network deployment

Industrial protocol integration

Role-aware monitoring access

Start with your operation

Ready to See Your Factory Differently?

Discover how RockLyzor can centralize your industrial data and give your team real-time operational visibility.